text.skipToContent text.skipToNavigation

Top Cover for CAM HD Assembly

2102088-002
419978-003
Diagnostic ECG
GE HealthCare
Outright
Add to Wish List
Login To Shop
Login To Shop
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Clear fail bias
  • Lead off detection
  • 4000Hz sampling rate
  • Patient isolation

Product Overview

The Top Cover is the case for the CAM-HD Acquisition Module is intended to acquire analog ECG signal, digitize it and transmit the signal to a host unit. The circuitry is designed to protect the host unit against the effects of cardiac defibrillator discharge to ensure recovery. This equipment will not cause abnormal operation of the patient’s cardiac pacemaker or other electrical stimulator. This device uses a computerized ECG analysis program which can be used as a tool in ECG tracing interpretation. This computerized interpretation is only significant when used in conjunction with clinical findings. To ensure accuracy, use only computer-generated tracings and not the display for physician interpretation. To ensure patient safety, use only parts and accessories manufactured or recommended by GE medical systems. This art is fixed in the CAM HD main unit and the wires are connected. Then CAM HD is connected to MAC machine. When the rhythm button is pressed the signal is given to the MAC Machine so it operates and prints the rhythm wave. Another two buttons has different functions. These buttons are used to start the operation on MAC machine.

Compatible Products

MAC 5500

MAC 5500

Substitute Parts :

Below is more information on the equivalent parts. Parts without a hyperlink are listed for reference only and are not available for purchase online.

Equivalent partPart Details
419978-003

Label Switch CAMHD